MoleQueue JSON-RPC Specification
JSON-RPC specification
This is the proposed communication protocol, it is neither final nor implemented!
The JSON-RPC 2.0 specification is here. In a nutshell, the protocol consists of three message types: requests, responses, and notifications. Every request must be met with a reply, and a notification is simply a request object without the id member.
Requests are JSON objects with three name/value pairs:
- method (String): The method requested.
- params (Array or Object): A parameters for the requested method.
- id (Value): A unique identifier.
Each request is met with a reply of the following format:
- result (Object, Array, or Value): The result of the request. Must not exist if there was an error.
- error (Error Object): A description of the error. Must not exist if no error occurred.
- id (Value): Must be the same as the identifier used in the request.
The Error object must contain an integer error code ("code") and a descriptive error string ("message"). An optional "data" object may provide more detailed information.
As mentioned above, notifications follow the same format as requests, but will omit the id name/value pair.
Implementation
Click for details about the MoleQueue JSON-RPC Implementation.
Specifying files
Files may be represented by either referring to a location on a local filesystem or providing a file's contents. The {FileSpec} object in the following sample messages refers to either of the following forms:
Filesystem path:
{
"path" : "/path/to/file"
}
or filename and contents:
{
"filename" : "string",
"contents" : "string containing file contents"
}
Supported Messages
The following sections detail the requests, responses, and notifications that MoleQueue recognizes:
List of available Queues/Programs
To obtain a list of the available Queues and the programs supported by them, submit a request for the method "listQueues" with no parameters. MoleQueue will reply with an object containing a dictionary with user-set names identifying each queue, along with an array of the programs supported by each queue.
Client request:
{
"jsonrpc": "2.0",
"method": "listQueues",
"id": "XXX"
}
Server response:
{
"jsonrpc": "2.0",
"result": {
"Big cluster SGE": [
"GAMESS",
"MOPAC",
"Gaussian",
"NWChem"
],
"Remote cluster PBS": [
"GAMESS",
"MOPAC",
"Gaussian",
"NWChem"
],
"Local": [
"GAMESS",
"MOPAC",
"Gaussian",
"NWChem"
]
},
"id": "XXX"
}
Request new job submission
Client request:
{
"jsonrpc": "2.0",
"method": "submitJob",
"params": {
"queue": "Remote cluster PBS",
"program": "MOPAC",
"description": "PM6 H2 optimization",
"inputFile": {FileSpec}
},
"id": "XXX"
}
Additional (optional) parameters may be used to tweak job behavior further. Default values are provided in parenthesis:
- additionalInputFiles: ([]) An array of additional {FileSpec} objects indicating supplemental files needed for the job to run. These are placed in the working directories of the job, but not explicitly called by the executable.
- cleanRemoteFiles: (false) If true, any remote working directories are deleted.
- retrieveOutput: (true) If true, output files are copied back into the local working directory.
- outputDirectory: (null) If not null, this must be a string specifying a path to place completed output files, instead of the local working directory.
- cleanLocalWorkingDirectory: (false) If true, the local temporary working directory will be removed on successful job completion.
- hideFromGui: (false) If true, the job will not be displayed in the MoleQueue GUI by default (useful for automated batch jobs).
- popupOnStateChange: (true) If true, a notification popup will be displayed system tray when the job's state changes.
- maxWallTime: (-1) The maximum time limit for a job to run in minutes. If less than or equal to zero, a queue-specific walltime is used instead. This option only has effect on remote queuing systems.
- numberOfCores: (1) The number of processor cores to request for this job.
Server response:
- If successful, some identifiers are returned:
{
"jsonrpc": "2.0",
"result": {
"moleQueueId": 17,
"workingDirectory": "/tmp/MoleQueue/17/"
},
"id": "XXX"
}
moleQueueId is a identifier that is unique to this instance of MoleQueue.
- If unsuccessful, an error is returned:
{
"jsonrpc": "2.0",
"error": {
"code": 32,
"message": "Cannot write to local directory \"/tmp/MoleQueue/17/\". Permission denied."
},
"id": "XXX"
}
Cancel submitted job
Client request:
Parameter is the MoleQueue id of the job to cancel:
{
"jsonrpc": "2.0",
"method": "cancelJob",
"params": {"moleQueueId" : 17},
"id": "XXX"
}
Server response:
Result is the MoleQueue id of the cancel job:
{
"jsonrpc": "2.0",
"result": 17,
"id": "XXX"
}
Notification of job state change
When a job changes state, MoleQueue will send a notification to all active connections of the following form:
{
"jsonrpc": "2.0",
"method": "jobStateChanged",
"params": {
"moleQueueId": 17,
"oldState": "RemoteQueued",
"newState": "Running"
}
}
Valid states are:
- None: Initial state of job, should never be entered.
- Accepted: Job has been received and is being prepared (Writing input files, etc).
- LocalQueued: Job is being queued locally, either waiting for local execution or remote submission.
- Submitted: Job has been submitted to a remote queuing system.
- RemoteQueued: Job is pending execution on a remote queuing system.
- RunningLocal: Job is running locally.
- RunningRemote: Job is running remotely.
- Finished: Job has completed.
- Killed: Job has been canceled by the user.
- Error: The job has encountered an error.
- Unknown: The job's status is not known or invalid.
Request Job Information
A client can request information about a Job by submitting a lookupJob request and providing a MoleQueue id:
{
"jsonrpc": "2.0",
"method": "lookupJob",
"params": {"moleQueueId" : 17},
"id": "XXX"
}
The server will respond with an object describing the Job's state using a similar JSON object as the submission request:
{
"jsonrpc" : "2.0",
"result" : {
"cleanLocalWorkingDirectory" : false,
"cleanRemoteFiles" : false,
"description" : "spud slicer 28",
"hideFromGui" : false,
"inputFile" : {FileSpec},
"additionalInputFiles" : [ {FileSpec}, {FileSpec}, ... ],
"jobState" : 0,
"localWorkingDirectory" : "/some/local/path",
"maxWallTime" : 1440,
"moleQueueId" : 17,
"numberOfCores" : 4,
"outputDirectory" : "",
"popupOnStateChange" : true,
"program" : "Quantum Tater",
"queue" : "Some big ol' cluster",
"queueId" : 7366,
"retrieveOutput" : true
},
"id": "XXX"
}
If the lookup fails (i.e. the request MoleQueue id is not known to the server), a simple error reply is sent with the requested MoleQueue id as the error.data value:
{
"error" : {
"data" : 17,
"code" : 0,
"message" : "Unknown MoleQueue ID"
},
"jsonrpc" : "2.0",
"id" : "XXX"
}